By Frank P. DiFilippo PhD (auth.), Marcelo F. Di Carli MD, Martin J. Lipton MD, FACR, FACC (eds.)

ISBN-10: 0387352759

ISBN-13: 9780387352756

ISBN-10: 038738295X

ISBN-13: 9780387382951

Cardiac puppy and hybrid PET/CT have revolutionized the sphere of cardiovascular imaging and supply new concepts for prognosis and administration of sufferers with cardiac stipulations. Cardiologists, radiologists, and nuclear drugs experts should have an updated reference during this quickly altering box to be able to such a lot successfully make the most of new expertise in perform. Cardiac puppy and PET/CT Imaging takes a step by step method of puppy and PET/CT instrumentation, imaging, and protocols. starting with imaging basics and progressing via complex dialogue of particular functions, this e-book is a complete resource of cardiac puppy and PET/CT info. Sections written via and for technologists in addition to dialogue of MRI and different imaging modalities upload to the well-rounded scope of this publication. A library of unique instances and several other hundred illustrations, many in colour, whole the textual content through highlighting interpretation and technical demanding situations in cardiac puppy and PET/CT.

Show description

Read Online or Download Cardiac PET and PET/CT Imaging PDF

Best nonfiction_9 books

Read e-book online Estimation of Microbial Protein Supply in Ruminants Using PDF

The Joint FAO/IAEA department of Nuclear concepts in nutrition and Agriculture has a protracted background of coordinating isotope aided learn initiatives for making improvements to animal productiveness in constructing international locations. those initiatives have eager about bettering the potency of animal creation via larger use of in the community on hand feed assets and those who don't compete with human foodstuff.

Methods of Seawater Analysis, Third Edition by PDF

Because the booklet first seemed in 1976, equipment of Seawater research has discovered common reputation as a competent and specific resource of data. Its moment prolonged and revised version released in 1983 mirrored the fast velocity of instrumental and methodological evolution within the previous years.

Neurophysiological Techniques: Applications to Neural - download pdf or read online

The improvement of neurophysiology, the learn of the job of dwelling apprehensive tissue, has relied seriously at the recommendations of electrophysiology. This emphasis is published in volumes 14 and 15 of this sequence, which exhibit how electrophysiological concepts might be utilized to investigate subject matters starting from ion channels to human habit.

Additional resources for Cardiac PET and PET/CT Imaging

Example text

The plane of bend is rotated by applying currents to these magnets that are approximately sinusoidal and 90 degrees out of phase. Thus, the deflected beam is caused to sweep along the circular tungsten target rings at the focus (5). Since the scanner is intended to image multiple slices, 4 target rings are provided and can be selected in sequence by varying the bend angle. An x-rayopaque housing (collimator) defi nes the x-ray beam to a fan shape (6) that rotates with the motion of the electron beam spot on the water-cooled target rings.

1. Thus, bone and lung imaging involve a high signal, so a good SNR can be obtained with lower radiation exposure or thinner slices. On the other extreme, brain imaging requires high radiation exposure and thicker slices. With the older single-slice spiral scanners, an important protocol design consideration involved selecting the scanning range or coverage. 1. Typical CT Contrast Ranges (Hounsfield units) Lung tissue or vessels surrounded by air Bone surrounded by soft tissue Contrast-enhanced blood vessels Muscle and organ tissue surrounded by fat Water surrounded by soft tissue Gray matter vs white matter in brain 1070 HU 500–3000 HU 200–400 HU 150–170 HU 60–70 HU 5–10 HU that restricted the selection of coverage including patient breath-holding interval, contrast injection rate and maximum contrast load, slice thickness and table speed, pitch, and so on.

Comput Graph Image Process. 1976;5:459. 14. Penczek PA, Renka R, Schomberg H. Gridding-based direct Fourier inversion of the threedimensional ray transform. J Opt Soc Am A Opt Image Sci Vis. 2004;21:499–509. 15. Boyd DP. A proposed dynamic cardiac 3-D densitometer for early detection and evaluation of heart disease. IEEE Trans Nucl Sci. 1979;26:2724. 16. Boyd DP, Couch JL, Napel SA, Peschmann KR, Rand RE. Ultrafast cine CT: Where have we been? What lies ahead? Am J Card Imaging. 1987;1:175. 17.

Download PDF sample

Cardiac PET and PET/CT Imaging by Frank P. DiFilippo PhD (auth.), Marcelo F. Di Carli MD, Martin J. Lipton MD, FACR, FACC (eds.)


by Anthony
4.4

Rated 4.42 of 5 – based on 24 votes